APPENDIX J: COMMUNICATION OPTION
STA SERIES AC CONTROLS
990-351
J-7
NAME COMMAND
DATA
SIZE
MONITOR “MR” Read
Read Schedule #
1 Byte
MONITOR “MS” Set
Set SCHEDULE #
1 Bytes
HIGH1C #
High current #1%
2 Bytes
HIGH2C #
High current #2%
2 Bytes
LOW1C #
Low current #1%
2 Bytes
LOW2C #
Low current #2%
2 Bytes
ANGLE LIMIT 1
Conduction limit #1
1 Byte
ANGLE LIMIT 2
Conduction limit #2
1 Byte
LIMIT #
Weld Count limit
2 Bytes
START
start
value
1
Byte
MODE
weld
mode
1
Byte
LOP
Low Pressure Limit
(0-9999)
2 Bytes
HIP
High Pressure Limit
2 Bytes
VOLTHIW1
W1 High Volt Limit
(0.00-9.99)
2 Bytes
VOLTLOW1
W1 Low Volt Limit
2 Bytes
VOLTHIW2
W2 High Volt Limit
2 Bytes
VOLTLOW2
W2 Low Volt Limit
2 Bytes
27
Bytes
Total
-------------------------------------------------------------------------
start
value:
MAINTAINED = 0
or
PULSED = 1
or
LATCHED = 2
or
SEAM =3
-------------------------------------------------------------------------
weld mode:
SPOT = 0
or
REPEAT = 1
or
SUCCESSIVE = 2
or
CHAINING = 3
-------------------------------------------------------------------------
Summary of Contents for Miyachi Unitek STA-100A
Page 1: ...990 351 Rev H AC WELDER STA SERIES OPERATION MANUAL...
Page 24: ......
Page 28: ......
Page 48: ......
Page 64: ......
Page 68: ...CHAPTER 5 MAINTENANCE STA SERIES AC CONTROLS 5 4 990 351...
Page 78: ......
Page 90: ......
Page 96: ...APPENDIX D SYSTEM TIMING STA SERIES AC CONTROLS D 2 990 351 Continuous Seam Weld...
Page 98: ...APPENDIX D SYSTEM TIMING STA SERIES AC CONTROLS D 4 990 351 Spot Welding...
Page 102: ......
Page 104: ......
Page 108: ......
Page 112: ......
Page 140: ......
Page 144: ......