Description
The Cascade Board gives the Control the ability
to operate up to four SCRs instead of just one.
The STA-600 and STA-800 use two Cascade
Boards in order to operate up to six and eight
SCRs respectively.
Cascade Board
Maintenance/Replacement
1
Disconnect the 26-pin ribbon cable connector from the AC Timer Main Board connected to J2.
2
Disconnect the 8-wire cable connector from each of the SCR Driver Boards connected to J4
(SCR1) through J7 (SCR4) as required.
3
Disconnect the 2-wire power connector from J8.
4
Slide the card out of the card cage.
5
Install or re-install the circuit board by
sliding it into the card cage.
6
Reconnect the 26-pin ribbon cable
connector from the AC Timer Main
Board to J2
7
Reconnect the 8-wire cable connectors
from each of the SCR Driver Boards to
J4 through J7 as required.
8
Reconnect the 2-wire power connector
to J8.
9
Slide the board into the card cage.
Cascade Board Connector Locations
J2
J8
J3
J4
J5
J6
J7
SCR4
SCR
3
SCR2
SCR1
Summary of Contents for Miyachi Unitek STA-100A
Page 1: ...990 351 Rev H AC WELDER STA SERIES OPERATION MANUAL...
Page 24: ......
Page 28: ......
Page 48: ......
Page 64: ......
Page 68: ...CHAPTER 5 MAINTENANCE STA SERIES AC CONTROLS 5 4 990 351...
Page 78: ......
Page 90: ......
Page 96: ...APPENDIX D SYSTEM TIMING STA SERIES AC CONTROLS D 2 990 351 Continuous Seam Weld...
Page 98: ...APPENDIX D SYSTEM TIMING STA SERIES AC CONTROLS D 4 990 351 Spot Welding...
Page 102: ......
Page 104: ......
Page 108: ......
Page 112: ......
Page 140: ......
Page 144: ......