STA SERIES AC CONTROLS
990-351
J-22
Section III. Maintenance
Remove/Replace the Communications Board
1
Disconnect the twenty-six pin ribbon cable connector from the AC Timer Main Board
connected to J2.
2
Disconnect the serial cable connector (coming from the external 9-pin connector) from J3.
3
Slide the card out of the card cage.
4
Install or re-install the circuit board by sliding it into the card cage.
5
Reconnect the 26-pin ribbon cable connector from the AC Timer Main Board to (coming
from the external 9-pin connector)
6
Reconnect the serial cable connector (coming from the external 9-pin connector) to J3.
7
Slide the board into the card cage.