APPENDIX B: WELD HEAD CONTROL INPUT/OUTPUT SIGNALS
SERIES 300 FAST RESPONSE WELD HEAD SYSTEM
B-6
990-115
To switch higher DC currents, either relay can be removed from its socket and reinserted two positions
to the right. Maximum relay current is limited to 1.0 amps. Polarity must now be observed.
CONTROL SIGNAL OUTPUT Connector
When the control signal output cable is connected between this connector and the CONTROL SIGNALS
connector on the HF2 or HF25 Power Supply, selecting a new schedule on the Weld Head Control
automatically selects the identical schedule number on the power supply. On the UB25 Power Supply, the
schedule must be separately set on the power supply See table B-2 for the connector pin assignments.
Table B-2. CONTROL SIGNAL OUTPUT Connector Pin Assignments
Pin
Signal Name
Function
1 2
0
Binary remote schedule select bit 1 (input 1)
2 2
1
Binary remote schedule select bit 2 (input 2)
3 2
2
Binary remote schedule select bit 3 (input 4)
4 2
3
Binary remote schedule select bit 4 (input 8)
12 2
4
Binary remote schedule select bit 5 (input 16)
5 2
5
Binary remote schedule select bit 6 (input 32)
14 2
6
Binary remote schedule select bit 7 (input 64)
7
Logic Out
Not implemented
6 Logic
In Not implemented
11, 13
Circuit Ground
DC Common
Shroud Chassis
Ground Power return
8, 9, 10, 15 None
Not used