CHAPTER 3: OPERATING INSTRUCTIONS
SERIES 300 FAST RESPONSE WELD HEAD SYSTEM
990-115
3-17
Table 3-3. Default System Parameters
4 Select
#
RESET ALL SCHEDULES/
PROGRAMS and press [ENTER]. The RESET
ALL SCHEDULES/ PROGRAMS PROCEED?
Option line appears.
5 Press [CHNG] to change NO to YES to reset all
weld schedules to their factory default settings.
Then press [ENTER]. When the reset process is
complete, the bottom of the screen will display
the message SCHEDULES/PROGRAMS ARE
RESET.
6 Press [MENU] to return to the MAIN MENU screen or press [RUN] to return to the weld graphical
RUN screen.
The
■
INSTALLATION Selection
The installation option provides narrative (no illustrations) instructions about how to set up the Weld
Head Control. At the MAIN MENU screen, press [ENTER] to select this option. Then, press [
►
] for
each new page of instructions. The best procedure is to follow the instructions in
Chapter 2: Getting
Started
in this manual.
System Parameters
Default
System Parameters
Default
Power Up Schedule
Last
Footswitch Weld Abort
On
End Weld Buzzer
Off
Debounce Time
10ms
Key Click
On
Unit Measure of Force
lb.
Relay 1 ON Condition
Alarm
Unit Measure of Distance
inch
Relay 2 ON Condition
Alarm
No Weld Material Check
Off
RESET DEFAULTS
■
RESET SYSTEM PARAMETERS
■
RESET ALL SCHEDULES/PROGRAMS
EPROM DATE: 02-13-95 11:19 V:1.00
RESET ALL SCHEDULES/PROGRAMS
PROCEED?
: NO
CHNG Change, ENTER accept