CHAPTER 3: OPERATING INSTRUCTIONS
SERIES 300 FAST RESPONSE WELD HEAD SYSTEM
3-16
990-115
CAUTION:
Do not attempt to re-adjust the factory-adjusted LVDT position.
WARNING
Be sure to observe the instructions given in the next step. If you do not perform it,
or you perform it improperly, you could be seriously injured. Up to 230 VAC
could be present within the chassis area.
7 Set the POWER switch on the rear panel of the Weld Head Control to OFF and disconnect the AC
input power.
8 Replace the Weld Head Control cover.
The
■
RESET to DEFAULTS Selection
The Reset To Defaults feature allows you to reset all system parameters or all weld schedules to their
original factory default settings.
NOTE:
You will not reset the weld counter.
1 From the MAIN MENU screen, select
#
RESET
TO DEFAULTS. The RESET DEFAULTS
screen will appear.
2 Select
#
RESET SYSTEM PARAMETERS and
press [ENTER]. The RESET SYSTEM
PARAMETERS PROCEED? Option line
appears.
3 Press [CHNG] to change NO to YES to reset all system parameters to their factory default settings,
then press [ENTER]. Table 3-3 lists the factory default settings. When the reset process is
complete, the bottom of the screen will display the message SYSTEM PARAMETERS ARE
RESET.
RESET DEFAULTS
■
RESET SYSTEM PARAMETERS
■
RESET ALL SCHEDULES/PROGRAMS
EPROM DATE: 02-13-95 11:19 V:1.00
▲▼
Select then ENTER
Summary of Contents for 300 Series
Page 1: ...990 115 REV Q ELECTRONIC WELD HEAD CONTROL 300 Series OPERATION MANUAL ...
Page 8: ...SERIES 300 FAST RESPONSE WELD HEAD SYSTEM viii 990 115 ...
Page 32: ......
Page 62: ......
Page 78: ......