SW1000 Installation and Operation Instructions
PUD3448R2-1
For Assistance: [email protected] +1 (909) 591-8431
Page 29
Using SwingGate Utility (cont.)
ITEM SETTING
DESCRIPTION
1
Panel Profile
Selects the panel profile:
•
Low - 39" barrier height, manufactured before to August 2015
•
Mid - 46" barrier height, manufactured before to August 2015
•
Low V2 - 39" barrier height, manufactured after August 2015
•
Mid V2 - 46" barrier height, manufactured after August 2015
The panel profile setting is factory-set and only needs to be changed if 1) the
barrier size has changed, or 2) the motor controller board has been replaced.
2
Home Position
Sets the barrier home position (closed position). To set the home position:
1) Enter
2000
in the text box.
2) Manually align the barrier to the correct home position.
3) Click
Set
.
The home position value must always be 2000. DO NOT change this value.
3
Security Alarm
Defines how far the barrier can be pushed/pulled from the home position before an alarm
sounds. When the barrier is manually moved beyond this position, in either direction, an
alarm sounds. The default setting is 100.
4
Panel Closing Time
Sets the length of time (in milliseconds) the barrier takes to move from the open position
to the closed position (home). The default setting is 4000ms.
This value should range from 2000ms to 4000ms. Setting the value outside this
range may result in injury to users or damage to the gate.
5
Breakaway
Sets the maximum force the motor uses to keep the barrier closed during an attempt to
force the barrier open. When the force applied to the barrier exceeds this setting, the
barrier gives way and an alarm sounds. The default setting is 55.
DO NOT set Breakaway to more than 100. Doing so may result in injury to users or
damage to the gate.
6
Presence Sensors Detection SW500 model only.
7
Panel Opening Time
Sets the length of time (in milliseconds) the barrier takes to move from the closed position
to the open position. The default setting is 4000ms.
This value should range from 2000ms to 4000ms. Setting the value outside this
range may result in injury to users and damage to the gate.
8
Impact
Sets the maximum force the motor uses to close the barrier upon impact with an object.
When the force required to close the barrier exceeds this setting, the barrier gives way
and an alarm sounds. The default setting is 40.
Setting the value too low/high may result in injury to users and damage to the gate.
9
Presence Sensors Alarm
SW500 models only.
10
Emergency Override
Direction
Sets the direction the barrier opens in emergency override mode. The default setting is
exit.
11
Dwell Time
Sets the time (in seconds) the barrier remains in the open position (allowing a user to
pass through the gate) before closing. The default setting is 6 seconds.
12
Alarm Duration
Sets the time (in seconds) the alarm sounds after the gate has been violated. The default
setting is 4 seconds.
13
Gate Information
Motor ID: Identifies the gate motor ID as either master or slave. Only SW1000T tandem
gates will have a slave motor ID.
Firmware Version: Displays installed firmware version.