SW1000 Installation and Operation Instructions
PUD3448R2-1
For Assistance: [email protected] +1 (909) 591-8431
Page 19
Emergency Override State Select
Breakaway Alarm Output
1
2
3
4
5
6
TB1
Common Ground
1
2
3
4
5
6
TB9
Common Ground
Emergency Override State Select Terminals
Figure 18
Exit Passage Terminals
Figure 19
This terminal is used to configure the Emergency
Override terminal (TB3-5) as either normally open
or normally closed. The default configuration
is normally open (no wire jumper installed). To
configure normally closed, install a wire jumper
between TB1-5 and common ground as shown in
[Figure 18].
This terminal is used to generate an output signal
when the barrier is forced open (breakaway alarm).
The output signal is a voltage-free, normally open,
momentary dry contact.
1. Locate the TB1 terminal block [Figure 18].
2. Using a wire jumper, jump TB1-5 and common
ground (TB1-1 through TB1-3) [Figure 18].
1. Locate the TB9 terminal block [Figure 19].
2. Connect wires to TB9-4 and common ground
(TB9-1 through TB9-3) [Figure 19].
Terminal
Description
1 - 3
Common Ground
4
N/A
5
Emergency Override
State Select
6
Barrier Hold Open
Terminal
Description
1 - 3
Common Ground
4
Breakaway Output
5
N/A
6
N/A