With Compressor running:
9.8.2
Verify the compressor shuts down when the tank pressure (
TANK
) reaches
50 PSI
(
344.7 KPA)
.
If the tank pressure (TANK) fails to reach 50 PSI (344.7 KPA), see section 13.15
for troubleshooting information.
With Compressor NOT running:
CAUTION
: Be careful when removing Air hose. System is pressurized.
9.8.3
Depressurize air Dryer (see section 8.3.3)
9.8.4
Verify the compressor turns on when the tank pressure (
TANK
) falls to
20
PSI
(
137.9 KPA)
.
9.8.5
Reconnect air hose.
If the Compressor Cycling fails either test described, it indicates a problem with
the Control Board which will need to be replaced. See sections 11.1 for part
detail and 11.5 for ordering information.
9.9 Testing High Compressor Last Run Time Alarm
CAUTION
: Be careful when removing Air hose. System is pressurized.
NOTE:
For this test, allow the Display Screen to cycle through the information
screens.
9.9.1
Start timing when the compressor turns on.