See section 13.5 for troubleshooting information.
8.6.2
Low Outlet Pressure Alarm –
Occurs when the Outlet Pressure (
OUTLET
) drops below the alarm set
point for more than one (1) minute.
See section 13.7 for troubleshooting information.
8.6.3
High Humidity Alarm –
Occurs when the Humidity level rises above the alarm set point for more
than one (1) minute. If this alarm is present for one (1) minute or more, the
air Dryer will go into
SHUTDOWN
mode to prevent saturated air from
being delivered to the supply line.
See section 13.9 for troubleshooting information.
8.6.4
High Cabinet Temperature Alarm -
Occurs when the temperature in the cabinet rises above 120° F (49° C) for
more than ten (10) seconds. If this alarm is present for one (1) minute or
more, the Air Dryer will go into
SHUTDOWN
mode to prevent damage to
the unit.
See section 13.12 for troubleshooting information.