8.11.1
Wire the Alarm Harness to monitoring device using the table below for
reference:
Wire #
Wire Color
Function
Power Fail
13
RED
SHORT
on Alarm
Alarm
16
BLACK
Common
14
BLACK
SHORT
on Alarm
Alarm
17
BLUE
Common
15
BLUE
OPEN
on Alarm
Alarm
18
BLACK
8.11.2
Connect the Alarm
Harness to the Alarm Port
on the back of the
Dehydrator.
8.12 Connecting via Web Browser
If the Air Dryer IS connected to an IP network:
The Air Dryer must be configured with a valid IP Address, Subnet Mask, and
Gateway Address for the network.
An IP cable is connecting the Air Dryer to the network.
Use a computer that is on the same network as the air Dryer.
Use Internet Explorer (6.0 or newer) or Mozilla Firefox Web Browser.
If the Air Dryer IS NOT connected to an IP network and has not been
configured with IP information:
Use the default IP Address (
192.168.1.102)
of the air dryer to connect.