Altec AIR, LLC
P210WLP Series Air Dryer User’s Guide
Page 26 of 96
P017455 – Rev. N
6.6 Installation Checklist
No shipping damage was detected.
Dryer location meets the following requirements:
o
Well ventilated
o
Free from abrasive dust or chemicals
o
Ambient temperature is between 40º – 85º F (5º - 30º C) for optimal
performance
System Pressure is set to 50 PSI.
No air leaks are present in the system.
No alarms are present on the Display Panel.
6.7 Moving Your Dryer
6.7.1
If relocating your dryer to another site of operation or packaging to ship for
service, perform the following steps prior to movement to ensure your dryer
continues to operate optimally.
6.7.1.1
Return the shipping block to the compressor assembly by re-inserting
the block between the compressor brackets and re-inserting the #8-32 x
¾” screw (
See section 6.5.4 for reference).
6.7.1.2
Remove any visible liquid water in the coalescing filter by
unscrewing the filter bowl and dumping the water. This process may be
made easier by removing the unit side panel.
NOTE
: Take care not to pinch the o-ring seal while returning the filter
bowl to the filter housing assembly