9.2 Measuring Compressor Amp Draw
With the Compressor running:
9.2.1
Open Panel (see section 8.8 ).
9.2.2
Locate wire #19
coming directly
from the
compressor
9.2.3
Use an Amp
Meter to measure
the running amps.
With the compressor running, the running amps should measure
1.0 amp or below
.
9.2.4
Close Panel.
If the compressor measures over 1.0 running amps, see section 13.16 for
troubleshooting information.