86
13.
Install a new gasket (PN 3500035-01) on the
motor controller, and make sure all of the bolt holes
line up. Note: The gasket can be held in place with a
dedicated gasket cement for installation purposes,
but do not use RTV sealant. (
Fig. 11
)
14.
Apply a strip of butyl sealant (part no. 3501917-00)
around the wire passage on the back of the motor
controller and trim it to fit cleanly with no gap. (
Fig. 12
)
NotE: INstall thE bEad oF butyl with thE NaRRow
sidE agaiNst thE suRFacE.
15.
Feed the loose wiring back through the wire
passage. Guide the controller into place, and mate it
against the RBH. Be accurate with the placement of
SAFETY CRITICAL ASSEMBLY: MakiNg thE 3 motoR
RiNg tERmiNal coNNEctioNs aNd RE-sEaliNg thE
iNVERtER may oNly bE pERFoRmEd by a tRaiNEd
tEchNiciaN usiNg oNly Alta MotoRs-appRoVEd,
calibRatEd tools aNd Alta MotoRs-pRoVidEd paRts.
FailuRE to Follow assEmbly iNstRuctioNs pRoVidEd
by Alta MotoRs may REsult iN iNcREasEd Risk oF a
VEhiclE FiRE aNd pERsoNal iNjuRy oR dEath. Alta
will hold thE sERVicE cENtER liablE FoR aNy damagE
oR iNjuRy that REsults FRom a FailuRE to comply
with thEsE iNstRuctioNs.
Fig. 11
Fig. 12
CHAPTER 6