2. Technical data
Tabella 1
POWER SUPPLY OF THE SYSTEM
230 Vac
POWER SUPPLY MOTOR AND ELECTRONIC
24Vcc
NOMINAL ABSORBTION
0,5A
BASCULE OVERFLOWING DOOR MAXIMUM HEIGHT
3000mm
SECTIONAL DOOR MAXIMUM HEIGHT
2700mm
MAXIMUM PUSH OF THE MOTOR (for 750 ms)
400N
MAXIMUM WIDTH OF SECTIONAL DOOR
3000mm
OPERATOR WEIGHT
6kg
OPERATOR DIMENSIONS
340 x 170 x 150 mm
LENGTH OF GUIDE
1500 mm x 2
EMERGENCY UNLOCKING
INTERNAL-EXTERNAL
TRANSMISSION
BY CHAIN
LIMIT SWITCHES
WITH ENCODER/YES
AUTOMATIC RECLOSING
SELECTABLE
SOFT STOP - SOFT START
PRESENT
DISPOSITIVE OF CONTROL
REMARK OF AN OBJECT DURING THE
MOTION
EMERGENCY STOP
PRESENT-ARREST OF MOVING
COURTESY LIGHT
24Vcc MAX 20W
PROTECTION DEGREE
IP 40
SERVICE
RESIDENTIAL 5 cycles/h
PRAKT/GAR.AS 60 PRAKT/GAR.AS 120
4500mm
8Kg
WARNING:
-Each intervention or beginning put on starting must be executed exclusively by qualified personnel.
-The automation must be regularly tested and checked in all its parts.
-The automation does not be utilized if any sort of intervention of maintenance or reparation must be execut-
ed.A problem of the automation or a bad balancing can provoke damage to people and/or things.
3. Assembly of the automation.
This chapter contains important information for a sure and correct installation. Follow scrupulously all the instructions
because a non correct assembly can provoke serious damage to people and/or things.
WARNING: Before starting the assembly of the automation remove all the mechanical unlocks.
3.1 Composition automatism
The composition of the automatism is described in figure 1.
Figure 1– Composition automatism
Table 1: Technical data