ITA
ENG
FRA
ESP
DEU
POR
6-1624050 rev.12 14/11/2012 Pag 6 di 9
Bring again the centre line of the door on the architrave, in a way that the
fixing clamp of the drive is exactly at the middle point of the door and
above the maximum position which the door can reach during the move-
ment.
Use a pen to mark the position of the holes of the clamp on the architrave.
Make a hole with a point of diameter 10 mm. on the marked positions.
figure 19
According to the type of the installation, fix the clamp (fig.20) to the archi-
trave by using suitable screws and plugs (not supplied: diameter S10 are
suggested).
figure 20
Fix the guide to the clamp on the architrave with the supplied bolt and
screw (fig.21).
figure 21
Modify the supplied fixing clamps in a way to install the drive to the level.
The maximum distance gettable between the ceiling and the drive, with
the supplied clamps, is of 45 cm. In order to obtain larger distances, it is
necessary to request some more clamps in addition.
The excess part of the clamp must be cut.
figure 22
figure 23
Arrange that the motor group with the drive is sus-
pended in a way that the points of suspension cor-
respond to the dimensions indicated on fig.23.
Warning: utilize plugs sufficiently strong to sus-
pend the automation (S8 diameter are suggested).
A
B
Mark the points (A and B) in which the fixing clamps (from the part of the mo-
tor) will be fixed to the ceiling.
By fixing the clamps, make sure that the guide is lined up with the fixing clamp
on the architrave and that is on level.
figure 24