C613-50102-01 REV C
Command Reference for x510 Series
661
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
P
OWER
OVER
E
THERNET
C
OMMANDS
SHOW
POWER
-
INLINE
Operational
Status
The operational status of the PSU hardware when this
command was issued:
•
On
if the PSU is installed and switched on.
•
Off
when the PSU is switched off (an RPS may be
connected to the switch to power PoE instead of the
PSU).
•
Fault
when there is an issue with the PSU hardware.
Power Usage
Threshold (%)
The configured SNMP trap / log threshold, as configured
from a
command.
Interface
The PoE port(s) in the format
portx.y.z
, where
x
is the
device number,
y
is the module number within the device,
and
z
is the PoE port number within the module.
Admin
The administrative state of PoE on a PoE port, either
Enabled
or
Disabled
.
Pri
The current PoE priorities for PoE ports, as configured from
a
command:
•
Low
displays when the
low
parameter is issued. The
lowest priority for a PoE enabled port (default).
•
High
displays when the
high
parameter is issued. The
second highest priority for a PoE enabled port.
•
Crit
displays when the
critical
parameter is issued.
The highest priority for a PoE enabled port.
Oper
The current PoE port state when this command was issued:
•
Powered
displays when there is a PD connected and
power is being supplied.
•
Disabled
displays when supplying power would make
the switch go over the power budget.
•
Off
displays when PoE has been disabled for the PoE
port.
•
F
ault
displays when a switch goes over its power
allocation.
Power
The power consumption in milliwatts (mW) for the PoE
port when this command was entered.
Device
The description of the connected PD device if a description
has been added with the
command. No description is shown for PDs not configured
with the
command.
Table 1:
Parameters in the
show power-inline
command output (cont.)
Parameter
Description