C613-50102-01 REV C
Command Reference for x510 Series
1964
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
V
IRTUAL
C
HASSIS
S
TACKING
(VCS
TACK
™) C
OMMANDS
SHOW
STACK
DETAIL
Stack member 2:
----------------------------------------------------------------
ID 2
Pending ID -
MAC address 0000.cd29.716d
Last role change Wed May 7 23:47:21 2013
Product type x510-52GTX
Role Backup Member
Status Ready
Priority 2
Host name awplus-2
S/W version auto synchronization On
Resiliency link status Successful
Stack port 2.0.51 status learned neighbor 3
Stack port 2.0.52 status learned neighbor 1
Stack member 3:
----------------------------------------------------------------
ID 3
Pending ID -
MAC address 0015.77c2.4d9d
Last role change Wed May 7 22:31:58 2013
Product type x510-52GTX
Role Backup Member
Priority 3
Host name awplus-3
S/W version auto synchronizaion On
Resiliency link status Successful
Stack port 3.0.51 status learned neighbor 1
Stack port 3.0.52 status learned neighbor 2
Table 4:
Parameters in the output from the
show stack detail
command
Parameter
Description
S/W version auto
synchronization
Whether the software-auto-synchronization feature is
turned on or off.
Host name
The host name of the stack member.
ID
Stack-ID.
Last Role Change
The date and time the stack member last changed its role in
the stack.
MAC address
Stack member MAC address.
Management VLAN
ID
The VLAN ID currently used for stack management: the
default is 4094.
Management VLAN
subnet address
The current stacking management VLAN subnet address.
Virtual Chassis
ID
The Virtual Chassis ID determines the last 12 bits of the
Virtual MAC address:
0000.cd37.0xxx