C613-50102-01 REV C
Command Reference for x510 Series
1796
AlliedWare Plus™ Operating System - Version 5.4.6-1.x
RADIUS C
OMMANDS
SHOW
RADIUS
Output
Figure 43-3:
Example output from the
show radius
command showing RADIUS
client status
RADIUS global interface name: awplus
Secret key:
Timeout: 5
Retransmit count: 3
Deadtime: 0
Server Address: 150.87.18.89
Auth destination port: 1812
Accounting port: 1813
Secret key: swg
Timeout: 5
Retransmit count: 3
Deadtime: 0show radius local-server group
Output Parameter
Meaning
Source
Interface
The interface name or IP address to be used for the source
address of all outgoing RADIUS packets.
Secret Key
A shared secret key to a radius server.
Timeout
A time interval in seconds.
Retransmit
Count
The number of retry count if a RADIUS server does not
response.
Deadtime
A time interval in minutes to mark a RADIUS server as “dead”.
Interim-Update
A time interval in minutes to send Interim-Update Accounting
report.
Group Deadtime
The deadtime configured for RADIUS servers within a server
group.
Server Host
The RADIUS server hostname or IP address.
Authentication
Port
The destination UDP port for RADIUS authentication requests.
Accounting Port
The destination UDP port for RADIUS accounting requests.