x510 Series Installation Guide for Virtual Chassis Stacks
81
Figure 35. Loosening the Captive Screws on the DC Connector
4. Remove 6.5mm (0.25 in.) of insulation from one end of the black
RETURN wire. Refer to Figure 36.
Figure 36. Stripping a Stranded Power Wire
5. Insert the black RETURN wire into the right connector and secure it by
tightening the captive screw with a flat-head screwdriver. Allied Telesis
recommends tightening the screw to 5 in-lbs. Refer to Figure 37.
Figure 37. Inserting the RETURN Wire
6.5 mm
(0.25 in.)