52
60549
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
58. CABINET
a. Remove six screws (three top and three bottom)
holding the hood assembly to the control hood
rear panel and cabinet top.
b. Disconnect the wires from the component parts
and ground wire in control hood and screw
holding ground wire to top.
NOTE: Refer to the appropriate wiring diagram
when rewiring the component parts.
c. Set control hood assembly out of the way.
d. Remove two screws from the bottom edge of
the front panel. Refer to Figure 12.
e. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 12.
f. Disconnect wires from door switch. Refer to
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
g. Remove two cabinet top hold-down screws.
Refer to Figure 30.
h. Lift cabinet top to a vertical position by hinging
it on the rear hold-down brackets. Refer to
Figure 36.
NOTE: When servicing, cabinet top may be raised
and hinged on the rear hold-down brackets or
supported against wall behind the dryer.
i. Carefully withdraw wire harness through hole
in cabinet top and lift the cabinet top assembly
off the hold-down brackets and set to the side.
Refer to Figure 36.
j. Disengage belt from motor and idler pulleys.
Refer to Figure 24.
NOTE: When reinstalling belt, be sure belt is
properly installed on motor and idler pulleys, and is
on the correct side of the idler lever, Figure 24. Belt
must be positioned around cylinder between center
and rear baffle screws with the ribbed surface
against the cylinder. After installing belt, rotate
cylinder manually to check that belt is properly
aligned.
k. If present, disconnect the cylinder light wires.
l. Remove four screws holding bulkhead to front
flange of cabinet. Lift complete bulkhead
assembly out of slots in cabinet. Refer to
Figure 30.
IMPORTANT: During reinstallation of front
bulkhead, be sure that air duct is properly
positioned with the flange inside of the felt seal on
the exhaust fan cover.
m. Manually rotate cylinder until one of the baffles
is at the 6 o’clock position and carefully remove
cylinder out through front of dryer.
NOTE: On models using unpainted, corrosion
resistant, coated steel cylinder, the cylinder must be
installed with the side marked “FRONT” or the
arrow pointing toward the front of the dryer.
n. Gas Models
(1) Disconnect igniter wires at disconnect
blocks, sensor wires from sensor terminals,
and wires from gas valve coils at the quick
disconnect blocks. Refer to Figure 14.
(2) Remove screw from right side of burner
housing, holding burner tube in place.
Refer to Figure 21.
(3) Gently move burner tube toward rear of
dryer to disengage tab from slot on left side
of burner housing. Refer to Figure 18.
(4) Carefully rotate burner tube and igniter
counterclockwise so tab is at 8 o’clock
position.
(5) Move air shutter end of burner tube slightly
to right and CAREFULLY remove burner
tube and igniter assembly out through front
of dryer.