60549
75
Section 8 Service Procedures Unique to Electronic Control Model Dryers
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Through Serial No. S6271975XG
Starting Serial No. S6271976XG
Figure 56
DRY1801S
TERMINAL
BLOCK
“L2”
TERMINAL
NEUTRAL
TERMINAL
GROUND WIRE
(GREEN)
ACCESS COVER
(SEE WARNING BELOW)
“L1”
TERMINAL
WIRE CONNECTION
DETAIL
POWER CORD
WIRING
GROUND
SCREW
GROUND WIRE
(GREEN)
WHITE
STRAIN
RELIEF
POWER CORD
(FOUR-WIRE)
MOUNTING
BRACKET
GROUND
SCREW
RED
WHITE
RED
BLACK
BLACK
Dryer is shown with the
access cover removed for
illustration purposes only.
To reduce the risk of an
electric shock, NEVER
operate the dryer with the
access cover removed.
W136
WARNING
Dryer is shown with the
access cover removed for
illustration purposes only.
To reduce the risk of an
electric shock, NEVER
operate the dryer with the
access cover removed.
W136
WARNING
DRY1803S
ACCESS COVER
(SEE WARNING BELOW)
WHITE
WIRES
NEUTRAL
TERMINAL
RED
WIRES
GROUND WIRE
(GREEN)
“L1”
TERMINAL
MOUNTING
BRACKET
POWER
CORD
WIRING
GROUND WIRE
(GREEN)
BLACK WIRE
TERMINAL BLOCK
“L2” TERMINAL
RED
WIRE
TERMINAL BRACKET
GROUND SCREW
WIRE
CONNECTION
DETAIL
GROUND
SCREW
STRAIN RELIEF
POWER CORD
(FOUR-WIRE)
NEUTRAL
(WHITE WIRE)
BLACK WIRE
SLOTTED HEX HEAD SCREWS
(Shipped inside the dryer)