60549
41
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To Test Drive Motor:
Refer to Figure 25
1. Remove motor and exhaust assembly.
2. Disconnect wires from motor switch.
NOTE: Refer to appropriate wiring diagram
when rewiring motor switch.
3. Put test meter probes on terminals 4 and 5. Meter
should read approximately one on Ohm scale.
4. Put test meter probes on terminal 4 and motor
frame. Meter should register “no reading” or
infinite.
5. Put test meter probes on terminal 5 and motor
frame. Meter should register “no reading or
infinite.
6. Put test meter probes on terminals 4 and 6. Meter
should register “no reading” or infinite.
Manually flex the centrifugal switch in motor,
meter should read approximately two on Ohm
scale.
7. Put test meter probes on terminals 1 and 2. Meter
should register “no reading.” Manually flex the
centrifugal switch in motor, meter should read
“zero” Ohms.
Figure 25
DRY956S
2
1
6
4
5
2
1
6
5
4
MOTOR AND
EXHAUST
ASSEMBLY
DRIVE
MOTOR
GROUND
WIRE
MOTOR
SWITCH