background image

1

CLOTHES DRYER

Technical Information

CAUTION

All safety information must be followed as provided in Service Manual of DV56H9000E(G)*.

WARNING

To avoid risk of electrical shock, personal injury or death, disconnect power to dryer 
before servicing, unless testing requires power.

Code No. : DC68-03171F_EN

IMPORTANT SAFETY NOTICE – “For Technicians only” 

This service data sheet is intended for

use by persons having electrical, electronic, and mechanical experience and knowledge at a level
generally considered acceptable in the appliance repair trade. Any attempt to repair a major
appliance may result in personal injury and property damage. The manufacturer or seller cannot
be responsible, nor assume any liability for injury or damage of any kind arising from the use of
this data sheet.
• 

Due to possibility of personal injury or property damage, always contact an authorized 

technician for servicing or repair of this unit.

• 

Refer to Service Manual (DV56H9000E(G)*) for detailed installation, operating, testing, 

troubleshooting, and disassembly instructions.

DV9000HA DRY_TECH MANUAL_DC68-03171F_EN.indd   1

2014-1-17   14:00:25

Summary of Contents for DV56H9000G Series

Page 1: ... and knowledge at a level generally considered acceptable in the appliance repair trade Any attempt to repair a major appliance may result in personal injury and property damage The manufacturer or seller cannot be responsible nor assume any liability for injury or damage of any kind arising from the use of this data sheet Due to possibility of personal injury or property damage always contact an ...

Page 2: ...splay panel in invalid state Check for Check if display PCB circuit has short FE Invalid power source frequency Check for Not using regular power source frequency Faulty power frequency sense circuit 9E1 Electronic control problem Over Voltage Error Check for Check PCB and Wire harness Check Power supply AE Electronic Control Problem Communication Error Check for Check PCB and Wire harness Replace...

Page 3: ...fluenced Sensor Bar Touch Data Mode Definition of Sensor Bar Touch Data Mode This action will put the dryer into sensor bar touch data mode Dryer will display Sensor Bar data This mode is the default initial service mode How to Enter With Power On press Mixed Load Bell and Temp Keys for 3 seconds Cycle Count Mode Definition of Cycle Count Mode This mode displays the total number of cycles the drye...

Page 4: ...crease the Display Mode ID Converting C F Celsius C 30 10 10 30 50 70 F 9 5C 32 Fahrenheit F 22 14 50 86 122 158 System Check Mode Definition of System Check Mode 02 will display System Check Mode 02 mode Progress Function Performed Start Pause Motor CW Relay On Heater Relay On Heater Relay Off Motor CW Relay Off How to Enter While in Power Off press the Dry Level Power keys simultaneously to put ...

Page 5: ...P C B assembly is designed to be durable and trouble free Do not replace the P C B assembly unless your diagnosis identifies the P C B assembly as the cause of the problem Follow the trouble diagnosis procedure when the micom is not operating normally to ensure you replace the correct parts ALIGNMENT AND ADJUSTMENTS WARNING To avoid risk of electrical shock personal injury or death disconnect powe...

Page 6: ...e motor continuous Rotor winding stator winding generator Is the motor protector normal If there are no problems with the items above the PCB assembly is defective Replace it 5 Blows fuses or trips circuit breaker Gas Model During ignition the dryer will draw X amps With the burner ON the dryer will draw X amps If the dryer is drawing amperages above this then suspect the house wiring fuse box or ...

Page 7: ...tion in exhaust Outside exhaust hood damper door stuck closed Exhaust too long too many elbows flex ductwork installed Poor intake air available for the dryer Incorrect tumbler speed Tumbler belt slipping Blower impeller bound check for foreign material in blower area Customer overloading dryer Check clothing labels for fabric content and cycle selected Clothes too wet due to insufficient spin out...

Page 8: ...hermostat 2 Heater resistance 13 Ω PIN 2 3 Heater resistance 34 Ω PIN 1 2 If resistance is infinity replace Heater Measure resistance of the following terminal 1 Door switch Off Terminal COM NC 1 3 1Ω Terminal COM NO 1 2 Ω 2 Door switch On Terminal COM NC 1 3 Ω Terminal COM NO 1 2 1Ω Belt Cut off S W Lever open Resistance value 1Ω Lever push Resistance value Ω Vent Sensing Thermistor Resistance 23...

Page 9: ...ce Radiant sensor Igniter 101D Resistance value 40 400 Ω If resistance is infinite replace Igniter Gas Valve 25M01A Valve 1 2 Resistance value about 1 2K Ω Valve 1 3 Resistance value about 0 5K Ω Valve 4 5 Resistance value about 1 2K Ω If resistance is infinity replace Valve Thermostat 60T21 Hi Limit 230F 50F Resistance value 1 Ω If resistance is infinity replace Thermostat DV9000HA DRY_TECH MANUA...

Page 10: ... and test Pink wire Pin 4 to Orange wire Pin 5 Approx Ω without laundry Approx 190Ω 10 with wet clothes Cycling Thermistor 1 Disconnect harness and test Blue wire Pin 3 to Red wire Pin 6 Approx 10 KΩ at 25 C 77 F Vent Thermistor 2 Vent sensor model only Disconnect harness and test Yellow wire Pin 2 to White wire Pin 7 Approx 238 23 KΩ at 25 C 77 F RY6 RY7 CN4 DV9000HA DRY_TECH MANUAL_DC68 03171F_E...

Page 11: ...L listed strain relief D Center silver colored terminal block screw E Neutral Grounding wire green yellow F Neutral wire white or center wire 1 Remove the External ground connector screw 2 Connect the ground wire green or unwrapped of the power cord to the external ground connector screw If you want to connect B Green or bare copper wire of power cord to the Neutral Post without assembling with A ...

Page 12: ...IRING DIAGRAM WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires power DV9000HA DRY_TECH MANUAL_DC68 03171F_EN indd 12 2014 1 17 14 00 32 ...

Page 13: ...lement considéré comme acceptable dans la réparations d appareils Toute tentative de réparation d un grand appareil peut entraîner une blessure à la personne et un dommage à l appareil Le fabricant ou le vendeur ne peut être responsable et n assume aucune responsabilité pour toute blessure ou tout dommage de quelque sorte que ce soit survenant du fait de l utilisation de cette fiche technique En r...

Page 14: ...ez si la carte de circuit imprimé a un court circuit FE Fréquence de source d alimentation non valide Diagnostic possible Non utilisation de la fréquence de source d alimentation normale Circuit de détection de fréquence d alimentation défectueux 9E1 Problème de commande électronique Erreur surtension Diagnostic possible Vérifiez la carte de circuit imprimé et le faisceau électrique Vérifiez l ali...

Page 15: ...ous passez en mode de réparation le cycle de fonctionnement n est pas affecté Mode de données du capteur Définition du mode de données du capteur Cette action met le sèche linge en mode de données du capteur Le sèche linge affiche les données du capteur Ce mode est le mode de réparation initial par défaut Pour sélectionner ce mode Avec l appareil sous tension appuyez sur les boutons Mixed Load Bel...

Page 16: ... Appuyez sur le bouton AdjustDown Diminuer pour diminuer le Display Mode ID ID du mode affichage Convertir les C F Celsius C 30 10 10 30 50 70 F 9 5C 32 Fahrenheit F 22 14 50 86 122 158 Mode de contrôle système Définition du mode de contrôle système 02 s affiche Mode de contrôle système mode 02 Fonction de progression activée Départ Pause Relais moteur CW activé Relais résistance activée Relais ré...

Page 17: ...arte de circuit imprimé est conçu pour être durable et sans dysfonctionnement Ne remplacez pas l ensemble de carte de circuit imprimé sauf si votre diagnostic identifie l ensemble de carte de circuit imprimé comme la cause du problème Suivez la procédure de diagnostic de panne quand le micom ne fonctionne pas normalement afin de vous assurez que vous remplacez les bonnes pièces ALIGNEMENTS ET RÉGL...

Page 18: ...rrectement fixée La rotation du moteur est elle continue enroulement du rotor enroulement du stator génératrice La protection du moteur est elle normale S il n y a aucun problème pour les éléments ci dessus l ensemble de carte de circuit imprimé est défectueux Remplacez la 5 Fait griller les fusibles ou déclenche le disjoncteur modèle à gaz Lors de l allumage le sèche linge consomme X A Lorsque le...

Page 19: ...conduit d évacuation est trop long trop coudé trop flexible La prise d air du sèche linge est mauvaise La vitesse du tambour est incorrecte La courroie du tambour est mal fixée La turbine du ventilateur est bloquée Vérifiez qu il n y a pas de corps étrangers au niveau du ventilateur L utilisateur a surchargé le sèche linge Vérifiez les étiquettes des vêtements et le cycle sélectionné Les vêtements...

Page 20: ... chauffant 13 Ω PIN 2 3 Résistance de l élément chauffant 34 Ω PIN 1 2 Si la résistance est infinie remplacez l élément chauffant Mesurez la résistance des bornes suivantes 1 Interrupteur du hublot arrêt Borne COM NC 1 3 1Ω Borne COM NO 1 2 Ω 2 Interrupteur du hublot actionné Borne COM NC 1 3 Ω Borne COM NO 1 2 1 Ω Commutateur d arrêt de la courroie Manette ouverte valeur ohmique 1 Ω Manette actio...

Page 21: ...apteur radiant Allumeur 101D Valeur ohmique 40 à 400 Ω Si la résistance est infinie remplacez l allumeur Soupape à gaz 25M01A Soupape 1 2 valeur ohmique 1 2 KΩ environ Soupape 1 3 valeur ohmique 0 5 KΩ environ Soupape 4 5 valeur ohmique 1 2 KΩ environ Si la résistance est infinie remplacez la soupape Thermostat régulateur 60T21 230F 50F Valeur ohmique 1 Ω Si la résistance est infinie remplacez le ...

Page 22: ...et le fil orange au niveau de la broche 5 Environ Ω sans linge Environ 190 Ω 10 avec linge mouillé Thermostat de cyclage 1 Débranchez le faisceau et testez le fil bleu au niveau de la broche 3 et le fil rouge au niveau de la broche 6 Environ 10 KΩ à 25 C 77 F Vent Thermostat 2 modèle de capteur de ventilation uniquement Débranchez le faisceau et testez Fiche de câble jaune 2 vers fiche de câble bl...

Page 23: ...ur de tension 1 9 cm homologué UL D Vis centrale argentée du bornier E Fil de terre neutre vert jaune F Fil neutre blanc ou central 1 Retirez la vis du connecteur de terre externe 2 Reliez le fil de terre vert ou sans habillage du cordon d alimentation au connecteur à vis de terre externe Pour brancher B fil vert ou en cuivre dénudé du cordon d alimentation à la borne neutre sans l assembler à A m...

Page 24: ...GE AVERTISSEMENT Afin d éviter tout risque d électrocution légère ou mortelle débranchez le sèche linge avant de le réparer sauf si le test nécessite sa mise sous tension DV9000HA DRY_TECH MANUAL_DC68 03171F_CFR indd 12 2014 1 17 14 03 26 ...