40
60549
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
g. Remove cylinder belt from idler and motor
pulleys. Refer to Figure 24.
h. Remove two screws holding motor mounting
bracket to dryer base. Refer to Figure 23. Then
pull complete assembly out thorough front of
dryer.
IMPORTANT: When reinstalling motor and
exhaust assembly, be sure wire harness on right side
is clipped to motor mounting bracket and is routed
along dryer base (between motor mounting bracket
and right side of cabinet). Refer to Figure 23. Tab on
rear of motor mounting bracket must be slid into
slot in dryer base. Be sure the belt has been installed
on the correct side of the idler lever. Refer to
Figure 24.
Figure 24
DRY862S
D248S
CORRECT WAY
INCORRECT WAY
IDLER
LEVER
IDLER
LEVER
IDLER
PULLEY
IDLER
PULLEY
BELT
MOTOR
PULLEY
BELT
MOTOR
PULLEY
BELT ON WRONG
SIDE OF IDLER LEVER