Programming NetMaster
F232152
30
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Reading Table 1
Use this table to set the amount of time for Power Fail
Reset.
The table range begins at 0 and ends at 255. Numbers
entered between 0 and 127 turn the option “OFF.” If a
number in this range is entered, the current cycle status
will be saved for up to six years. When power is
restored, the cycle will begin where it was interrupted.
If 133 is entered, the current cycle will be saved for up
to five minutes. If power is not restored within five
minutes, the control will erase the cycle status. The
minimum power failure time is five minutes. The
maximum power fail reset time is 127 minutes.
“+034”
Power Fail Reset Value
Power Fail Reset ON/OFF
Power Fail Reset Time
0 – 127
OFF
0
133 – 255
ON
5 – 127 min.
Table 1