Start Up
Startup Sequence
On power-up, the drive will initialize
and status information will scroll across
the LCD display.
After initialization, the Device/Axis
state will be shown on the LCD display.
In this example, the current state is
STANDBY.
Device and Axis States
The following tables lists all the possible states and their descriptions for Device
and Axis.
If a boot fault occurs during initialization, a
fault number shows up on the screen with
the format, “BFxxx”, where “BF” stands for
boot fault and “xxx” refers to the fault code.
In this example, fault BF003 is shown.
For a list of other types of possible faults, see
.
Device State
Description
STANDBY
The drive is waiting to receive configuration information from the controller.
CONNECTING
The drive is trying to establish communication with the EtherNet/IP controller.
CONFIGURING
The drive is receiving configuration information from the controller.
SYNCING
The drive is waiting for a successful Group Sync service.
CONN_TIMEOUT
The drive is trying to establish communication with the EtherNet/IP controller but the
connection has timed out.
DUPLICATE_IP
The drive has detected another device on the network with the same IP address.
FWUPDATE
The drive is updating the firmware.
Axis State
Description
INITIALIZING
The drive is initializing the motion connection.
PRECHARGE
The drive is ready for mains input power.
STOPPED
The drive is in the Stopped state and awaiting a motion command.
STARTING
The drive has received a motion command and is transitioning to the Running state from
the Stopped state.
RUNNING
The drive is enabled and/or running.
TESTING
The drive is actively executing a test procedure, for example, a hookup test.
STOPPING
The drive is decelerating to a stop as the result of a disable.
ABORTING
The drive is decelerating to a stop as the result of a fault or an abort request.
MAJOR FAULTED
The drive is faulted due to an existing or past fault condition.
START INHIBITED
The drive has an active condition that inhibits it from being enabled.
SHUTDOWN
The drive has been shut down.
VOLTS
AMPS
HERTZ
RUN
FWD
REV
PROGRAM
Summary of Contents for PowerFlex 527
Page 4: ...4 Rockwell Automation Publication520 UM002B EN E December 2017 Summary of Changes Notes...
Page 8: ...8 Rockwell Automation Publication 520 UM002B EN E December 2017 Table of Contents Notes...
Page 173: ...Rockwell Automation Publication520 UM002B EN E December 2017 173 Notes...
Page 174: ...174 Rockwell Automation Publication 520 UM002B EN E December 2017 Notes...
Page 175: ......