Chapter 6
Network Control of Safe Torque-Off
9.
Verify that the Network Status (NET) status indicator is alternating red/
green on the correct drive.
10.
Power cycle the drive.
11.
Follow your company-prescribed procedures to functionally test the
replacement drive and system and to authorize the system for use.
Scenario 3 – Replacement Integrated Safety Drive SNN is Different from Original and no Safety
Signature Exists
1.
Remove and replace the existing integrated safety drive.
2.
Right-click the replacement drive and choose Properties.
3.
Click the Safety tab.
4.
Click Reset Ownership.
5.
Click OK.
6.
Power cycle the drive.
7.
Follow your company-prescribed procedures to functionally test the
replacement drive and system and to authorize the system for use.