134
Rockwell Automation Publication 520-UM002B-EN-E - December 2017
Appendix A
Supplemental Drive Information
Environmental Specifications
ODVA
ODVA conformance tested to EtherNet/IP specifications
Lloyd’s Register
Lloyd’s Register Type Approval Certificate 15/80016(E1)
IEEE P1668
Product meets the requirements of IEEE P1668
RoHS
Compliant with the European “Restriction of Hazardous Substances” Directive
The drive is also designed to meet the appropriate portions of the following specifications:
NFPA 70 - US National Electrical Code
NEMA ICS 7.1 - Safety standards for Construction and Guide for Selection, Installation and Operation of Adjustable
Speed Drive Systems.
Certifications
PowerFlex 527
Specifications
PowerFlex 527
Altitude:
Without derating:
With derating:
See
Current Derating Curves on page 15
for derating guidelines.
1000 m (3300 ft) max.
Up to 4000 m (13,200 ft) max., with the exception of 600V drives @ 2000 m (6600 ft)
max.
Max. Surrounding Air
Temperature
Without derating:
With derating:
See
Current Derating Curves on page 15
for derating guidelines.
-20...50
C (-4...122
F)
-20...60
C (-4...140
F) or -20...70
C (-4...158
F) with optional Control Module Fan
kit.
Storage Temperature:
Frame A...D:
Frame E:
-40...85
C (-40...185
F)
-40...70 °C (-40...158 °F)
Atmosphere:
Relative Humidity:
0...95% noncondensing
Shock:
Vibration:
Complies with IEC 60068-2-27
Complies with IEC 60068-2-6:2007
Conformal Coating:
Complies with:
IEC 60721-3-3 to level 3C2 (chemical and gases only)
Surrounding Environment
Pollution Degree
Pollution Degree 1 & 2:
See
Pollution Degree Ratings According to EN 61800-5-1 on page 37
for descriptions.
All enclosures acceptable.
Sound Pressure Level
(A-weighted)
Frame A & B:
Frame C:
Frame D:
Frame E:
Measurements are taken 1 m from the drive.
Maximum 53 dBA
Maximum 57 dBA
Maximum 64 dBA
Maximum 68 dBA
IMPORTANT
Drive
must not
be installed in an area where the ambient atmosphere contains volatile or
corrosive gas, vapors or dust. If the drive is not going to be installed for a period of time, it must
be stored in an area where it will not be exposed to a corrosive atmosphere.
Frame
Size
Operating and Nonoperating
Nonoperating (Transportation)
Force
(Shock/Vibration)
Mounting Type
Force
(Shock/Vibration)
Mounting Type
A
15 g / 2 g
DIN rail or screw
30 g/ 2.5 g
Screw only
B
15 g / 2 g
DIN rail or screw
30 g/ 2.5 g
Screw only
C
15 g / 2 g
DIN rail or screw
30 g/ 2.5 g
Screw only
D
15 g / 2 g
Screw only
30 g/ 2.5 g
Screw only
E
15 g / 1.5 g
Screw only
30 g/ 2.5 g
Screw only
Summary of Contents for PowerFlex 527
Page 4: ...4 Rockwell Automation Publication520 UM002B EN E December 2017 Summary of Changes Notes...
Page 8: ...8 Rockwell Automation Publication 520 UM002B EN E December 2017 Table of Contents Notes...
Page 173: ...Rockwell Automation Publication520 UM002B EN E December 2017 173 Notes...
Page 174: ...174 Rockwell Automation Publication 520 UM002B EN E December 2017 Notes...
Page 175: ......