132
Rockwell Automation Publication 520-UM002B-EN-E - December 2017
Chapter 7
Troubleshooting
Drive Behavior, FLT Mxx Fault Codes
Exception Fault Code
Exception Text
Induction
Motor
Fault Action
Best Available Stopping
Action (applies to major
faults)
Ignore
Alarm
Minor
Fault
Major
Fault
FLT M10 – CONTROL MODULE
OVERTEMPERATURE FL
Control Module Overtemperature Fault
X
X
Disable and Coast
FLT M19 – DECEL OVERRIDE
Decel Override
X
X
X
X
X
Disable and Coast
FLT M21 – MOTOR TEST FAILURE Motor Test Failure
X
X
Disable and Coast
FLT M26 – RUNTIME ERROR
Runtime Error
X
X
Disable and Coast
FLT M28 – SAFETY COMM
Safety Module Communication Error
X
X
Disable and Coast
Drive Behavior, NODE FLT xx Fault Codes
Exception Fault Code
Exception Text
Induction
Motor
Fault Action
Best Available Stopping
Action (applies to major
faults)
Ignore
Alarm
Minor
Fault
Major
Fault
NODE FLT 01 –
LATE CTRL UPDATE
Control Connection Update Fault
X
X
Current Decel and Disable
NODE FLT 02 – PROC WATCHDOG Processor Watchdog Fault
X
X
Disable and Coast
NODE FLT 03 – HARDWARE
Hardware Fault
X
X
Disable and Coast
NODE FLT 05 – CLOCK SKEW FLT
Clock Skew Fault
X
X
Disable and Coast
NODE FLT 06 – LOST CTRL CONN Lost Controller Connection Fault
X
X
Current Decel and Disable
NODE FLT 07 – CLOCK SYNC
Clock Sync Fault
X
X
Disable and Coast
NODE FLT 09 –
DUPLICATE IP ADDRESS
Duplicate IP Address Fault
X
X
Disable and Coast
Summary of Contents for PowerFlex 527
Page 4: ...4 Rockwell Automation Publication520 UM002B EN E December 2017 Summary of Changes Notes...
Page 8: ...8 Rockwell Automation Publication 520 UM002B EN E December 2017 Table of Contents Notes...
Page 173: ...Rockwell Automation Publication520 UM002B EN E December 2017 173 Notes...
Page 174: ...174 Rockwell Automation Publication 520 UM002B EN E December 2017 Notes...
Page 175: ......