72
PegaSys Operating Modes
Valid booking with start of permanently open mode
Credential with standard function and permanently open function:
GREEN --- GREEN --- Long GREEN
Signaling for a credential that only has the permanently open function:
Long GREEN
Booking memory entry:
Door permanently open
.
Valid booking with end of permanently open mode
Credential with standard function and permanently open function:
GREEN --- GREEN --- long RED
Signaling for a credential that only has the permanently open function:
Long RED
Booking memory entry:
Toggle closed
Signaling: Data transmission
Data transmission
PegaSys door fitting 2.0, electronic cylinder and locker lock: Orange flashes (
),
followed by another signal.
PegaSys door fitting 2.1: blue (
), followed by another signal.
Meaning: Data transmission. During the data exchange between a system card and another PegaSys
Offline component, the LED flashes. Thereafter, the PegaSys Offline component signals whether or not the
read/write procedure has been successfully completed.
No credential/no card in the field
RED
Meaning: No credential/no card in the read area. The electronics have been activated, but could not find
any credential/card.
Booking memory entry: No entry.
Visual and audible signals for system cards (PegaSys version 2.x)
Note
§
System cards are
door initialization cards
,
time initialization cards
,
blocking list cards
and
upload cards
.
GREEN --- GREEN
Meaning: Read/- write confirmation for system cards. Data has successfully been read from or written to the
system card.
RED --- RED
Meaning: Read/write error. Failed to read data from or write data to the system card.
Remedy: Hold the system card in front of the PegaSys Offline component a second time.
Booking memory entry: No entry.
Summary of Contents for PegaSys
Page 2: ......
Page 4: ......
Page 7: ...Installation Instructions for PegaSys Electronic Door Fittings ...
Page 8: ......
Page 34: ......
Page 35: ...Installation Instructions for PegaSys Electronic Lock Cylinders ...
Page 36: ......
Page 52: ......
Page 53: ...Installation Instructions for PegaSys Electronic Locker Locks ...
Page 54: ......
Page 61: ...PegaSys Locker Locks 57 Locking lever type 4 6 5 mm angled ...
Page 63: ...PegaSys Teach In or NetworkOnCard Operation Valid for all PegaSys offline components ...
Page 64: ......
Page 78: ......
Page 83: ......