58
PegaSys Locker Locks
3.10 Technical data
Power supply
Battery
One lithium battery, type AA, 3.6 V.
Battery life
Up to 50,000 opening cycles, depending on the reading technology,
the design, the installation conditions and the operating modes.
Locker opening when battery is
empty
Possible by exchanging the battery.
Environmental conditions
Operating temperature
+10 °C to +50 °C
Large variations in temperature will reduce the lifetime of the
batteries.
Protection category
Corresponds to IP 20
Installation location
Indoors
Humidity
10 °C to 90 °C, non-condensing.
Not suitable for changing rooms with integrating washing and shower
facilities.
Other
Dimensions (W × H × D in mm) 44,6 × 148,4 × 35,9
Cylinder
Thread M18, thread length 22 mm
Credentials
MIFARE or LEGIC (depending on the order)
Signaling
Visual and audible signals
Locking lever
10 mm hole, straight or angled
Standards
DIN EN 300330-1 Publication date: 2006-08
DIN EN 300330-2 Publication date: 2006-08
OENORM EN 301489-1 V 1.5.1, 2005-03-01
OENORM EN 301489-3 V 1.4.1, 2003-01-01
RL 1999/5/EG, RegTP Vfg. No. 30/2006
Summary of Contents for PegaSys
Page 2: ......
Page 4: ......
Page 7: ...Installation Instructions for PegaSys Electronic Door Fittings ...
Page 8: ......
Page 34: ......
Page 35: ...Installation Instructions for PegaSys Electronic Lock Cylinders ...
Page 36: ......
Page 52: ......
Page 53: ...Installation Instructions for PegaSys Electronic Locker Locks ...
Page 54: ......
Page 61: ...PegaSys Locker Locks 57 Locking lever type 4 6 5 mm angled ...
Page 63: ...PegaSys Teach In or NetworkOnCard Operation Valid for all PegaSys offline components ...
Page 64: ......
Page 78: ......
Page 83: ......