53
Set mode menu
0HQX&RROLQJIDQVHWWLQJ
This is to select operation condition of the cooling fan. Please set it ON when the main unit is
installed in less ventilated area.
1.
Press and hold FUNC key to enter the set
mode. Press dial to select menu 29.
Factory default setting is [AUTO].
2.
Rotate the right dial and select a desired.
This setting becomes effective regardless
of bands and VFOs.
3.
Press any key to set and exit, or press the
dial or UP/DOWN keys to set and move to
another menu.
AUTO :
Cooling fan turns when the main unit becomes hot, while transmitting and for 2
minutes after transmitting.
It turns off automatically when cooled down.
ON :
Cooling fan turns continuously. It turns always while powered on.
HTEMP :
It turns only when inside temperature excesses above 70°C (158°F).
This parameter is only recommended while monitoring in a silent place by
minimizing fan noise.