A 100
Alcatel Vacuum Technology France - ATP User’s Manual
GB 00406 - Edition 04 - March 00
2/4
1
2
15
16
J4
J2
R15
S3
+ 72V
0 V
+ 15 V
+ 5 V
0 V GND
Vn
Défaut
Stand by
Démarrage
Verte
Connecteur
Entrées/Sorties
J5
Paramétrage
liaison série
Réglage
vitesse
Connecteur
alimentation
Trou de fixation Ø 3
Rouge
Jaune
Jaune
J1
160.02
90.17
Integrable Brick & Board controller
technical characteristics
Power supplying of
ACT 200 T Board
ACT 200 T Board
Dimensions
Connector : type Molex Series 30-69 P.N. 09 - 91 -
0700 equipped with 7 contacts P.N. 08 - 050 - 0106
DC voltage necessary to supply the board:
+ 72 V / 1.4 A ± 1 V
+ 15 V / 0.25 A ± 100 mV
+ 5 V / 0.4 + 50 mV / - 100 mV
Functions of these integrable controllers (
see B 130
).
Pump at speed
Pump starting
Fault
Stand by
Green
Yellow
Red
Yellow
Power supply
connector
Speed
setting
Serial link
setting
Input/Output
connector
Holes diam 3
ACT 200 T Board
It can be installed in an Europe size rack:
Height: 100 mm - Depth: 180 mm
Outside depth: 210 mm