![Alcatel Vacuum Technology Adixen ATP 100 User Manual Download Page 111](http://html.mh-extra.com/html/alcatel-vacuum-technology/adixen-atp-100/adixen-atp-100_user-manual_2891737111.webp)
E 100
Maintenance counters
for ACT 1000T controller
Alcatel Vacuum Technology France - ATP User’s Manual
1/3
GB 00446 - Edition 01 - March 97
Principle
The ball bearings can be regreased 2 times before to be
changed.
The maintenance counter allows to account for these
different operations (0-1-2) and to set their frequency limits
(in hours).
When leaving the factory, the
«BEARING MAINT.»
counter is reset at «0» and the frequency fixed at 5000h:
this can be modified depending on the defined values in
the greasing schedule (
see D 40
) or on the acquired
know-how.
Maintenance operations are automatically displayed by
the controller since this reset.
The user will have to perform the regreasings or ball
bearing replacement and to increase the
«BEARING
MAINT.»
and
«BEARING LIMIT»
counters.
Example of operation with a maintenance frequency fixed to 5000h*.
0
5000
1
10000
2
0
15000
5000
0
5000
D37
10000
D37
"BEARING MAINT"
"BEARING LIMIT"
"BEARING MAINT"
"BEARING LIMIT"
"BEARING MAINT"
"BEARING"
"BEARING LIMIT"
15000
D24
Counter
(period in h)
"BEARING MAINT"
Counter
Message
Maintenance
operation
"BEARING LIMIT"
"LIMIT"
1st lubrication
+
Increase
counter to 1
and
counter to 10000
New
bearings
2nd lubrication
+
Increase
counter to 2
and
counter to 15000
Bearings
replacement
+
Increase
counter to 0
and
counter to 5000
+
Reset
counter
*The maintenance frequency for regreasing or ball bearing replacement could be modified along the life time of the bearings: