General Port Commands
Page 184
7710 SR OS Interface Configuration Guide
General Port Commands
port
Syntax
port
{
port-id
|
bundle-id
|
bpgrp-id
|
aps-id
}
no port
{
bundle-id
|
bpgrp-id
|
aps-id
}
Context
config
Description
This command enables access to the context to configure ports, multilink bundles, and bundle protection
groups (BPGs). Before a port can be configured, the chassis slot must be provisioned with a valid card type
and the MDA parameter must be provisioned with a valid MDA type. (See
card
and
mda
commands.)
Default
No ports are configured. All ports must be explicitly configured and enabled.
Parameters
port-id —
Specifies the physical port ID in the
slot/mda/port
format.
bundle-id —
Specifies the multilink bundle to be associated with this IP interface. The command syntax
must be configured as follows:
Syntax
: bundle-
type
-
slot/mda.bundle-num
bundle
-
ppp
-
slot/mda.bundle-num
(Creates a multilink PPP bundle.)
bundle
: keyword
slot
: card/mda
slot
numbers
bundle-num
:
1 — 256
For example:
router1>config# port bundle-1/1.1 (multilink PPP bundle)
aps-id —
This option configures APS on un-bundled SONET/SDH ports. All SONET-SDH port parameters,
with certain exceptions, for the working and protection circuit ports must be configured in the
config>port>aps-group-id
context. The working and protection circuit ports inherit all those
parameters configured. The exception parameters for the working and protect circuits can be configured
in the
config>port>sonet-sdh
context. Exception list commands include:
clock-source
[no] loopback
[no] report-alarm
section-trace
[no] threshold
When an
aps-group-id
is created all applicable parameters under the port CLI tree (including
parameters under any submenus) assume
aps-group-id
defaults, or when those are not explicitly
specified, default to SONET/SDH port defaults for any SONET port.
.All but a few exception SONET/SDH parameters for the working channel port must be configured in
the
config>port>aps>sonet-sdh
context. The protection channel inherits all the configured parameters.
The exception parameters for the protection channel can be configured in the
config>port>aps>sonet-
sdh
context.
Summary of Contents for 7710 SR SONET
Page 6: ...Page 6 7710 SR OS Interface Configuration Guide Table of Contents...
Page 8: ...Page 8 7710 SR OS Interface Configuration Guide List of Tables...
Page 10: ...Page 10 7710 SR OS Interface Configuration Guide List of Figures...
Page 14: ...Preface Page 14 7710 SR OS Interface Configuration Guide...
Page 16: ...Getting Started Page 16 7710 SR OS Interface Configuration Guide...
Page 18: ...Page 18 7710 SR OS Interface Configuration Guide Configuration Notes on page 107...
Page 166: ...Service Management Tasks Page 152 7710 SR OS Interface Configuration Guide...
Page 354: ...Multi Chassis Redundancy Commands Page 328 7710 SR OS Interface Configuration Guide...
Page 494: ...Standards and Protocols Page 494 Standards and Protocols...
Page 496: ...Index Page 496 7710 SR OS Interface Configuration Guide...