Interface Configuration
7710 SR OS Interface Configuration Guide
Page 389
OTU Output —
The following table describes the OTU output fields.
Label
Description
OTU Status
Status of the OTU (Optical Transport Unit): enabled or disabled.
When OTU is enabled, and additional layer of framing encapsulates an
MDA's natively programmed mode of operation, 10-Gigabit Ethernet
LAN or WAN, adding SONET-Like Framing with FEC (Forward Error
Correction). When OTU is disabled, the MDA operates in a 10-Giga-
bit Ethernet LAN or WAN as per Ethernet provisioning.
FEC Mode
Type of FEC (Forward Error Correction) in effect: g709, enhanced or
disabled. When g709 is selected, the standard FEC method is used.
When enhanced is selected, a proprietary FEC algorithm is used that
extends optical reach in long haul applications. When disabled the
bytes that are reserved for FEC in the OTU frame are transmitted as
zeros and the FEC decoder is bypassed, but OTU framing is still in
effect.
Data Rate
This indicates the data rate at which the port is operating. When OTU
is encapsulating 10-Gigabit Ethernet WAN, the data rate is 10.709 Gb/
s, the G.709 standard OTU2 data rate. When OTU is encapsulating 10-
Gigabit Ethernet LAN, the data rate is either 11.049 Gb/s or 11.096
Gb/s, depending on the otu2-lan-data-rate configuration parameter of
the port's OTU parameters. These data rates (11.049 Gb/s and 11.096
Gb/s) are considered OTU2e data rates that are non-standard or over-
clocked with respect to G.709, but have become widely used in optical
networking to transport un-altered 10-Gigabit Ethernet LAN payloads.
Cfg Alarms and
Alarm Status
This indicates the alarms that shall be reported when raised or cleared.
Alarms that are not in this list will not be reported when they are raised
or cleared but will appear in the Alarm Status.
SF/SD Method
This indicates the selected method for declaring the SF (Signal Fail) or
SD (Signal Degrade) alarm. When BIP8 is selected, the error rate of
SM-BIP8 errors in the OTU frames is used to declare SF or SD (This is
very similar to SONET SF/SD which uses a rate of B2 errors). When
FEC is selected, the rate of corrected bits is used to declare SF or SD.
This effectively indicates that the link would be degraded (SD) or
failed (SF) if FEC was disabled and gives the user an early warning
that the link is degrading or is about to fail.
SF Threshold
This is the configured error rate threshold at which the SF (Signal Fail)
alarm will be raised.
SD Threshold
This is the configured error rate threshold at which the SD (Signal
Degrade) alarm will be raised.
Summary of Contents for 7710 SR SONET
Page 6: ...Page 6 7710 SR OS Interface Configuration Guide Table of Contents...
Page 8: ...Page 8 7710 SR OS Interface Configuration Guide List of Tables...
Page 10: ...Page 10 7710 SR OS Interface Configuration Guide List of Figures...
Page 14: ...Preface Page 14 7710 SR OS Interface Configuration Guide...
Page 16: ...Getting Started Page 16 7710 SR OS Interface Configuration Guide...
Page 18: ...Page 18 7710 SR OS Interface Configuration Guide Configuration Notes on page 107...
Page 166: ...Service Management Tasks Page 152 7710 SR OS Interface Configuration Guide...
Page 354: ...Multi Chassis Redundancy Commands Page 328 7710 SR OS Interface Configuration Guide...
Page 494: ...Standards and Protocols Page 494 Standards and Protocols...
Page 496: ...Index Page 496 7710 SR OS Interface Configuration Guide...