Page 62
2. Remote Controller Functions
2.1 LCD Wired Remote Controller
2.1.1 LCD Wired Remote Controller KJR-12B/DP(T) (Standard)
The KJR-12B/DP(T) wired remote controller is standard for Duct type.
i) Buttons and Functions
MODE BUTTON
TIMER OFF BUTTON
AUXILIARY ELECTRICAL HEATER
RESET BUTTON
ON/OFF BUTTON
ADJUST BUTTON
SWING BUTTON
LOCK BUTTON
TIMER
ON
TIMER
OFF
FOLLOW
ME
AUXIL
HEATER
MODE
RESET
LOCK
FANS PEED
ECO
SWING
TEMP
• Used to select the operating mode
• For cooling-only units, there is no
HEAT function.
• Used to automatically
turn on the air conditioner
at a specif ied time.
• Used to automatically
turn off the air condi-
tioner at a specif ied
time.
• Allows the remote
control to act as a remote
thermostat and relay
temperature information
from its current location.
• The Auxiliary Electric Heater
warms up the unit in cold
climates.
• If pressed during HEAT mode,
the electric heater function
becomes ineffective.
• Used to restore the system
to its default settings.
• Used to start/stop the air
conditioner.
• Press these two buttons
at the same time to switch
between Celsius and
Fahrenheit (some models)
• The SWING button starts
and stops the louver
movement and sets the
desired airflow direction.
• Used to activate/deacti-
vate ECONOMY Mode, in
which the unit maintains
a comfortable tempera-
ture during sleeping hours.
• Used to select the
fan speed.
• Used to lock/unlock
the current setting.
LowM
ed.
High
AUTO
COOL DRY HEAT FAN
TIMER ON BUTTON
ECONOMY BUTTON
F AN SPEED BUTTON
FOLLOW ME BUTTON
ii) LCD Screen
1
2
1
12
1
12
Displays the selected
operating mode
Follow me
Displayed when the
FOLLOW ME feature
is activated
ON/OFF
Displayed when
the air
conditioner is
on
Timer
The “ON” sign lights up
when the TIMER ON
function is activated
The “OFF” sign lights up
when the TIMER OFF
function is activated
Temperature display
Displays the current set
temperature
Lock
Displayed when the LOCK
mode is on
Fan speed
Displays the
selected fan
speed
Operation mode
Pr
oduct Featur
es
Summary of Contents for YFAD-100R-01M25
Page 15: ...Page 15 4 Centre of gravity 18K 24K...
Page 16: ...Page 16 36K...
Page 17: ...Page 17 48K 60K...
Page 19: ...Page 19 DFMD 100N 01M25...
Page 20: ...DFMD 100N 01T35 Page 20...
Page 22: ...DFMD 160N 01M25 Page 22...
Page 27: ...Page 27 YFAD 100R 01M25...
Page 28: ...YFAD 100R 01T35 Page 28...
Page 29: ...Page 29 YFAD 140R 01T35...
Page 30: ...YFAD 160R 01T35 Page 30...
Page 56: ...Page 56 11 Static Pressure 18K 24K...
Page 57: ...Page 57 30K 36K 48K 60K...
Page 93: ...Page 93 Design Static Pressure 3 Dynamic Losses For dynamic losses please refer to below image...