80
10 - TECHNICAL INFORMATION
DOMESTIC HOT WATER PRODUCTION
COOLING
HEATING
Twu [°C] = leaving exchanger water temperature
Tae [°C]: Outdoor exchanger inlet air temperature
1. Normal operating range
2. Normal operating range, with modulating fans
3. Operating range where the use of ethylene glycol is mandatory in relation to the
temperature of the water at the outlet of the user side exchanger
4. Operating range with modulating compressor
Twu [°C] = leaving exchanger water temperature
Tae [°C]: Outdoor exchanger inlet air temperature
1. Normal operating range
2. Operating range with modulating compressor
3. Operation range with fans and compressors in modulation
4. Operating range with use of the heater (Optional)
Twu [°C] = leaving exchanger water temperature
Tae [°C]: Outdoor exchanger inlet air temperature
1. Normal operating range
2. Operating range with modulating compressor
3. Operation range with fans and compressors in modulation
4. Operating range with use of the heater (Optional)
OPERATING RANGE
PAC BT 5kW - 7kW -
9kW
PAC BT 12kW -
14kW - 17kW
PAC BT 5kW - 7kW -
9kW
PAC BT 12kW -
14kW - 17kW
PAC BT 5kW - 7kW -
9kW
PAC BT 12kW -
14kW - 17kW
Summary of Contents for PAC BT Series
Page 1: ...Installation and operating manual PAC BT 5 kW to 17 kW M0GC6UN16 02 Nov 2016 English version...
Page 2: ......
Page 4: ......
Page 87: ...Airwell Residential AWAU PAC BT UE 5KW H11 AWHK PAC BT UI 5 9KW H11 42 64 3 4 5 XL kW kW kW...
Page 91: ...Airwell Residential 42 64 4 5 7 XL kW kW kW AWAU PAC BT UE 7KW H11 AWHK PAC BT UI 5 9KW H11...
Page 95: ...Airwell Residential 42 64 5 6 8 XL kW kW kW AWAU PAC BT UE 9KW H11 AWHK PAC BT UI 5 9KW H11...
Page 111: ......