12-11
CONTROL SYSTEM
SM DLSDCI 3-A.1 GB
TROUBLESHOOTING
Service Manual
Multi Cinco 100 DCI
12-11
Revision 0
VLOW
Turbo
HIGH
MEDIUM
LOW
DT
3
2
1
0
-1
4
12.4.2.2
Indoor fan control - Cool Mode
When T/H/M/L speed is set by user, IFAN will work in constant requested speed.
When Auto-Fan speed is set by user, IFAN speed will be set according to LOAD(n) as in
the following graph:
IF V L O W
IF L O W
IF M E D
IF H IG H
IF T U R B O
2 5
L O A D (n )
IF A N S p e e d
1 0 0
7 5
5 0
12.4.2.3
Indoor fan control – Heat Mode
12.4.2.3.1 IFAN Operation in set speed
When in heat mode, including protections and except Deicing, IFAN will be working
according to the graph below.
12.4.2
Indoor Fan Control
12.4.2.1 Indoor fan control - FAN Mode
•
When T/H/M/L speed is set by user, IFAN will work in constant requested speed.
•
When Auto-Fan is set by user, IFAN speed will be set according to the following graph:
Mode
Power Shedding OFF
Power Shedding ON
Cooling
No limit
Nominal Cooling
Heating
No limit
Nominal heating
NLOAD limits as a function of power shedding: