CONTROL SYSTEM
SM DLSDCI 3-A.1 GB
12.9.3.2 ODU Model Selection Jumper/DIP – J2, J3, J4, J5, J6, J7
ODU Model
J7
J6
J5
J4
J3
J2
M (DCI 100 / INV40)
OFF
OFF
ON
ON
OFF
ON
N (DCI 125 / INV50)
OFF
OFF
ON
ON
ON
OFF
AB (DCI 100 C.R / INV38)
OFF
ON
ON
ON
OFF
OFF
AE (DCI100 3PH / INV40T)
OFF
ON
ON
ON
ON
ON
AF (DCI125 3PH / INV50T)
ON
OFF
OFF
OFF
OFF
OFF
AG (DCI140 3PH / INV60T)
ON
OFF
OFF
OFF
OFF
ON
AO (DCI 125 1-Phase Driver)
ON
OFF
ON
OFF
OFF
ON
AP (DCI 140 1-Phase Driver)
ON
OFF
ON
OFF
ON
OFF
12.9.3.3 TPT test Jumper/DIP – J8
Position
Status
Description
0
Open (Disconnected)
Normal Operation (Default)
1
Close (Shorted)
Test enabled
Used for technician testing – TPT. For normal use must be set to OFF (0).
12.9.4
Dip-Switch Setting Table
Storm 4-6HP DCI
J1 J2 J3 J4 J5 J7 J8 J9
DLS 036 (JAMAICA 38/40/40T INV)
19
ON
OFF
DLS043 (JAMAICA 50/50T INV)
19
ON
OFF
EMD100 (EMD 40/40T INV)
18
ON
OFF
EMD125 (EMD 50/50T INV)
18
ON
OFF
EMD140 (EMD 60/60T INV)
18
ON
OFF
LSN
J2 J3 J5 J7 J8 J9 J10 J12
LSN 009
24
ON
OFF
LSN 012
24
ON
OFF
LSN 018
24
ON
OFF
LSN 021
25
ON
OFF
LSN 024
25
ON
OFF
Storm DCI
J1 J2 J3 J4 J5 J7 J8 J9
DLS 018 (JAMAICA 22 INV)
12
ON
OFF
DLS 021 (JAMAICA 27 INV)
12
ON
OFF
DLS 024 (JAMAICA 30 INV)
12
ON
OFF
DLS 030 (JAMAICA 35 INV)
12
ON
OFF