![Airwell DLS 30 DCI Service Manual Download Page 31](http://html.mh-extra.com/html/airwell/dls-30-dci/dls-30-dci_service-manual_2880105031.webp)
5-13
PERFORMANCE DATA & PRESSURE CURVES
SM DLSDCI 3-A.1 GB
ID COIL ENTERING AIR DB/WB TEMPERATURE
[C0]
OD COIL ENTERING
AIR DB
TEMPERATURE
[C0] DATA 22/15 24/17 27/19 29/21 32/23
-10 - 20
(protection range)
TC
80 - 110 % of nominal
SC
80 - 105 % of nominal
PI
25 - 50 % of nominal
25
TC 8.22 8.75 9.29 9.83 10.36
SC 7.04 7.18 7.33 7.47 7.61
PI 2.05 2.09 2.13 2.17 2.21
30
TC 7.82 8.36 8.90 9.43 9.97
SC 6.86 7.00 7.15 7.29 7.43
PI 2.29 2.33 2.37 2.41 2.45
35
TC 7.43 7.96
8.50
9.04 9.57
SC 6.68 6.83
6.97
7.11 7.26
PI 2.53
2.57
2.61
2.65 2.69
40
TC 7.03 7.57 8.10 8.64 9.18
SC 6.51 6.65 6.79 6.94 7.08
PI 2.77 2.81 2.85 2.89 2.93
46
TC 6.56 7.09 7.63 8.17 8.70
SC 6.29 6.44 6.58 6.72 6.87
PI 3.06 3.10 3.14 3.18 3.22
5.4
DLS 36 DCI - H11
5.4.1
Cooling Capacity (kW)
LEGEND
TC - Total Cooling Capacity, KW
SC - Sensible Capacity, KW
PI - Power Input, KW
WB - Wet Bulb Temp. (
⁰
C)
DB - Dry Bulb Temp. (
⁰
C)
ID - Indoor
OD - Outdoor