![Airwell DLS 30 DCI Service Manual Download Page 10](http://html.mh-extra.com/html/airwell/dls-30-dci/dls-30-dci_service-manual_2880105010.webp)
2-3
PRODUCT DATA SHEET
SM DLSDCI 3-A.1 GB
2.3 DLS 30 DCI
Model Indoor Unit
DLS 30 DCI R410A AW
Model Outdoor Unit
AWAU-YBDE030-H11
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Average
Warmer
Capacity
(1)
kW
7.5 (2.8÷8.4)
8.6 (2.8÷9.4)
Pdesign
kW
7.5
8.6
8.6
SEER / SCOP
(1)
W/W
4.5
3.6
4.1
Energy efficiency class
C
A
A+
Annual energy consumption
kWh
1,450
4,955
2,611
Tbiv
o
C
N/A
-3
6
Tol
o
C
N/A
-15
-10
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Circuit breaker rating
A
20
INDOOR
Fan type & quantity
Centrifugal x 1
Fan speeds
T/H/M/L
RPM
800/670/550
Air flow
(2)
T/H/M/L
m3/hr
1320/1150/935
External static pressure
Min-Max
Pa
25-80
Sound power level
(3)
H/M/L
dB(A)
63/60/54
Sound pressure level
(4)
H/M/L
dB(A)
48/44/40
Moisture removal
l/hr
1.8
Condensate drain tube I.D
mm
19
Dimensions
WxHxD
790x256x749
790x256x749
Weight
kg
31
Package dimensions
WxHxD
960x300x855
959x315x854
Packaged weight
kg
33.5
Units per pallet
units
6
Stacking height
units
6
OUTDOOR
Refrigerant control
EEV
Compressor type, model
Twin Rotary DC Inverter
Fan type & quantity
Axial x 1
Fan speeds
RPM
200-800 (continuous)
Air flow
Max.
m3/hr
3,400
Sound power level
Nom.
dB(A)
68
Sound pressure level
Nom.
dB(A)
56
Dimensions
WxHxD
mm
900x860x340
Weight
kg
66
Package dimensions
WxHxD
mm
985x905x435
Packaged weight
kg
68.5
Units per pallet
Units
6
Stacking height
units
2 levels
Refrigerant type
R410A
Refrigerant charge(standard connecting
tubing length)
Kg(7.5m)
2.10
Additional charge per 1 meter
gr / 1m
7.5m < 0gr < 15m < 50gr per 1m < 50m
Connections
between units
Liquid line
In.(mm)
3/8”(9.53)
Suction line
In.(mm)
5/8”(15.88)
Max.tubing length
m.
50
Max.height difference
m.
25
Operation control type
Remote control
Heating elements
kW
Others
(1) Rating conditions in accordance with EN14825 and EN14511 (for ducted units).