![Airwell DLS 30 DCI Service Manual Download Page 24](http://html.mh-extra.com/html/airwell/dls-30-dci/dls-30-dci_service-manual_2880105024.webp)
5-6
PERFORMANCE DATA & PRESSURE CURVES
SM DLSDCI 3-A.1 GB
5.2.2
Heating Capacity
ID COIL ENTERING AIR DB
TEMPERATURE [°C]
OD COIL
ENTERING AIR
DB/WB
TEMPERATURE
[°C]
DATA
15 20 25
-15/-16
TC 4.84 4.50 4.16
PI 1.25
1.38
1.50
-10/-12
TC 5.38 5.05 4.71
PI 1.50 1.63 1.76
-7/-8
TC 5.80 5.46 5.12
PI 1.70 1.82 1.95
-1/-2
TC 6.00 5.66 5.32
PI 1.79 1.92 2.05
2/1
TC 6.14 5.80 5.46
PI 1.86 1.98 2.11
7/6
TC 7.94
7.60
7.26
PI 1.95
2.08
2.21
10/9
TC 8.38 8.04 7.70
PI 2.07 2.20 2.32
15/12
TC 8.81 8.48 8.14
PI 2.19
2.31
2.44
15-24
TC
85 - 105 % of nominal
(Protection Range)
PI
80 - 120 % of nominal
LEGEND
TC - Total Cooling Capacity, KW
SC - Sensible Capacity, KW
PI - Power Input, KW
WB - Wet Bulb Temp. (
⁰
C)
DB - Dry Bulb Temp. (
⁰
C)
ID - Indoor
OD - Outdoor