12-2
CONTROL SYSTEM
SM DL
F
1
-A.1 GB
12.5.2.1 Compressor Min On/Off time
Compressor minimum ON and OFF time is 3 minutes except during protections.
12.5.2.2 Compressor
Startup
% "=>Î>q ! !
; @W
12.5.2.3 Compressor start up fail
'@ %"+>
second and up to 3 minutes it will report a compressor lock or unusal behavior.
12.5.2.4 Compressor operation while OFAN Error
' W[@+> %
to OFF until OFAN error will recover.
12.5.2.5 Speed Change Limitations
Acceleration and deceleration will be 1 RPS/sec.
12.5.2.6 Speed Step Limitations
12.5.2.7 Illegal
frequencies
Illegal Frequencies are values that the unit is not allowed to be working at. The frequencies and values within
tolerance of ±2 Hz are not allowed.
12.5.2.8 Compressor shutdown Cases
#
Shutdown Reason
1
Single: ODU NLOAD=0 (or IDU protections)
2
Single: IDU change to STBY.
3
Multi: All IDU`s become inactive.
4
Deicing (both when going from heat to cool and from cool to heat)
5
ODU Protections
6
Sensor fault: according sensor fault list
7
HPS protection
8
LPS protection
9
OFAN-ERR (Up and Down)
10
PFC TRIP
11
W
Time (min)
Max Allowed
Frequency
Compressor Starts up
(Actual Freq>0)
Maximum Allowed Frequncy
after compressor starts up
Step1Freq
Step1Time
Step2Time
Step3Time
Step4Time
Step2Freq
Step3Freq
Step4Freq
Summary of Contents for DLF 18 DCI
Page 11: ...4 2 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 2 Outdoor Unit YBDE 018 024...
Page 65: ...12 37 CONTROL SYSTEM SM DL A 1 GB 12 9 5 Remote Control RC 8 Reset Operation...
Page 69: ...12 41 CONTROL SYSTEM SM DLF 1 A 1 GB 12 11 7 Segment Legend 7 7 segments lege end...
Page 91: ...14 2 SM DLF 1 A 1 GB EXPLODED VIEWS AND SPARE PARTS LISTS 14 2 Indoor Unit DLF 18 DCI...
Page 96: ...14 7 EXPLODED VIEWS AND SPARE PARTS LISTS SM DLF 1 A 1 GB 14 5 Indoor Unit DLF 24 DCI...