8-1
ELECTRICAL DATA
SM DLF 1-A.1 GB
8.
ELECTRICAL DATA
8.1 Single
Phase
Units
MODEL
DL
F
18
DL
F
24
1 PH ,220-240VAC ,50HZ
Power Supply
Outdoor
Indoor or Outdoor
Connected to
15A
15A
Maximum Current
Inrush Current
(c)
45 A
Starting Current
(d)
15 A
15A
20 A
Circuit Breaker
(a)
Power supply can be connected in both ways:
To outdoor unit to supply both outdoor and indoor unit.
To outdoor unit and to Indoor unit separately.
(b) Communication wires must be separated from the power wires and should be shielded type, earth connected at
both ends.
(c) Inrush current is the current when power is up (charging the DC capacitors at outdoor unit controller).
(d) Starting current is the current peak when starting the compressor.
NOTE
:
Power wiring cord should comply with local lows and electrical regulations requirements.