![Airwell DLF 18 DCI Technical Manual Download Page 76](http://html1.mh-extra.com/html/airwell/dlf-18-dci/dlf-18-dci_technical-manual_2880115076.webp)
13-7
TROUBLESHOOTING
SM DL
F
1
-A.1 GB
No
Problem
AO
5
4
3
2
1
1
OCT is shorted/disconnected
Yes
0
0
0
0
1
2
CTT is shorted/disconnected
Yes
0
0
0
1
0
3
HST is shorted/disconnected
Yes
0
0
0
1
1
4
OAT is shorted/disconnected
Yes
0
0
1
0
0
5
OMT is shorted/disconnected
Yes
0
0
1
0
1
6
RGT is shorted/disconnected
Yes
0
0
1
1
0
7
RLT is shorted/disconnected
Yes
0
0
1
1
1
8
High pressure protection
Yes
0
1
0
0
0
9
Low pressure protection
Yes
0
1
0
0
1
10
No communication to Driver
Yes
0
1
0
1
0
11
x
Compressor IPM Fault
x
IPM Driver Pin
x
Compressor Current Sensor Fault
Yes
0
1
0
1
1
12
No Water Flow (For Hydro Units only)
Yes
0
1
1
0
0
13
Refrigerant Leakage
No
0
1
1
0
1
14
x
DC over voltage
x
DC under voltage
Yes
0
1
1
1
0
15
x
AC under voltage
x
AC over Voltage
x
Zero Crossing detection
Yes
0
1
1
1
1
16
x
Mismatch between IDU & ODU models
x
'<=
x
=<='
Yes
1
0
0
0
0
17
No Communication
Yes
1
0
0
0
1
18
System Over Power
Yes
1
0
0
1
0
19
>
PFC Current sensor
>
Missing phase
>
Phase order mismatch
>
PFC Trip (Oveload)
Yes
1
0
0
1
1
20
Heat sink Over Heating
Yes
1
0
1
0
0
21
Deicing
No
1
0
1
0
1
22
Compressor Over Heating
Yes
1
0
1
1
0
23
Compressor Over Current
Yes
1
0
1
1
1
24
No OFAN Feedback (Both OFAN_UP or OFAN_DN)
Yes
1
1
0
0
0
25
x
OFAN IPM fault
x
OFAN IPM Driver Pin
Yes
1
1
0
0
1
26
Compressor Lock
Yes
1
1
0
1
0
27
Indoor Coil defrost
Yes
1
1
0
1
1
28
Abnormal system behave
No
1
1
1
0
0
29
Indoor Sensor fault
Yes
1
1
1
0
1
30
x
Outdoor Coil Overheating
x
Indoor Coil Overheating
Yes
1
1
1
1
0
31
Operation conditions are exceeded
Yes
1
1
1
1
1
1 - ON, 0 - OFF
Only one code is shown. Order of priority is lower to the higher number. Diagnostics is continuously
ON as long power is on.
Summary of Contents for DLF 18 DCI
Page 11: ...4 2 OUTLINE DIMENSIONS SM DLF 1 A 1 GB 4 2 Outdoor Unit YBDE 018 024...
Page 65: ...12 37 CONTROL SYSTEM SM DL A 1 GB 12 9 5 Remote Control RC 8 Reset Operation...
Page 69: ...12 41 CONTROL SYSTEM SM DLF 1 A 1 GB 12 11 7 Segment Legend 7 7 segments lege end...
Page 91: ...14 2 SM DLF 1 A 1 GB EXPLODED VIEWS AND SPARE PARTS LISTS 14 2 Indoor Unit DLF 18 DCI...