4.Web Management: System of POE-GSH1008R-130
79
AirLive POE-GSH1008R-130 User Manual
4. Click Apply to apply the change.
Parameter description:
Power Supply Configuration
1. Ping Check :
Enable Ping Check function can detects the connection between PoE port and
power device. Disable will turn off the detection.
2. Port :
This is the logical port number for this row.
3. Ping IP Address :
The PD's IP Address the system should ping.
4. Interval Time(sec) :
Device will send checking message to PD each interval time. default: 30, range:
10-120 sec.
5. Retry Time :
When PoE port can't ping the PD, it will retry to send detection again. When the
third time, it will trigger failure action. default: 3, range: 1-5.
6. Failure Log :
Failure loggings counter.
7. Failure Action :
The action when the third fail detection.