Pcbrm15 & PCBRM System 5.2 User’s Manual Chapter 5: Maintenance/Parts
Part No. 4005.00.906
5-4
5.1 Solder Removal
•
Use Solder Bailer to transfer solder to a container with a capacity of 150 cubic inches or more.
Most of the solder can be removed with the bailer. Weight of solder is 35 lbs.
CAUTION!!
S
OLDER IS
HOT. U
SE
E
XTREME
C
AUTION
.
5.2 Pump Cleaning
Pump bracket, housing, impeller and shaft are all rugged, stainless steel. The pump bearings are
lubricated with high temperature grease. Heat is not the main reason for their failure – rather it is dirt
(dross, flux).
Note:
W
HEN REMOVING PUMP FOR CLEANING
,
SOLDER MUST BE REMOVED FROM POT
.
To Clean Pump
1. Hold pump in a vise for disassembly.
2. Do not remove leveling screws.
3. Clean all parts (except pump bearings) thoroughly:
•
Use mineral spirits to remove dirt.
•
Use a wire brush for easy to get at areas.
•
Use a scraping tool for hard to reach areas.
4. Inspect parts before reassembling (especially pump bearings). Check bearings for free, smooth
action – no binding or rough action, if so, replace.
Assembly (see Disassembly Procedure)
5. Be certain when assembling the pump housing to pump bracket that the alignment guides are
lined up exactly. This will insure that the pump is level when installed back onto the machine. If
they are not lined up or if the leveling screws were removed, the result will be an un-level solder
wave and very poor soldering or desoldering processes.
6. Spin pump shaft to be certain that the pump is assembled correctly before placing back on
machine.
Note:
O
NCE PUMP IS INSTALLED ONTO THE MACHINE
,
CHECK THE LEVEL OF THE PUMP
. I
F
ADJUSTMENT IS NEEDED
,
REFER TO PUMP LEVELING PROCEDURE
.
Summary of Contents for PCBRM15
Page 1: ...PCBRM15 PCBRM System 5 2 ...
Page 2: ......
Page 4: ......
Page 6: ...PCBRM15 PCBRM System 5 2 User s Manual Table of Contents 4005 00 906 ...
Page 28: ...PCBRM15 PCBRM System 5 2 User s Manual Chapter 3 Set Up Installation Part No 4005 00 906 3 2 ...
Page 42: ...PCBRM15 PCBRM System 5 2 User s Manual Chapter 3 Set Up Installation Part No 4005 00 906 3 16 ...
Page 70: ...Pcbrm15 PCBRM System 5 2 User s Manual Chapter 5 Maintenance Parts Part No 4005 00 906 5 2 ...
Page 88: ...Pcbrm15 PCBRM System 5 2 User s Manual Chapter 6 Troubleshooting Part No 4005 00 906 6 2 ...
Page 92: ...Pcbrm15 PCBRM System 5 2 User s Manual Chapter 6 Troubleshooting Part No 4005 00 906 6 6 ...
Page 94: ...Pcbrm15 PCBRM System 5 2 User s Manual Chapter 7 Schematics Part No 4005 00 906 7 2 ...
Page 96: ......
Page 98: ......
Page 100: ......
Page 101: ......
Page 102: ......
Page 104: ......
Page 106: ......
Page 108: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......
Page 120: ......