146
Installation and Verification Manual
3
Performance Tests
Note Attenuator
Setting
N/A
N/A
‘No Trouble’ Min Sens
Pass/Fail
Additional Attenuation
Typ > 1 dB
N/A
–26 dBm PWR meas
–28 dBm
–24 dBm
OTU-1 Frequency
2666.0570 MHz
2666.0572 MHz
–9 dBm PWR meas
–11 dBm
–7 dBm
‘No Trouble’ Max Sens
Pass/Fail
Power Meter check
–9.5
–8.5
Optical Receive Port (9.95 and 10.7
Gb/s)
Laser LED ON
Pass/Fail
Note Attenuator
Setting
N/A
N/A
‘No Trouble’ Min Sens
Pass/Fail
Additional Attenuation
Typ > 1 dB
N/A
–14dBm PWR meas
–15.5 dBm
–12.5 dBm
OC-192/STM-64
Frequency
9953.2799 MHz
9953.2801 MHz
Option 112
Laser LED ON
Pass/Fail
Note Attenuator
Setting
N/A
N/A
‘No Trouble’ Min Sens
Pass/Fail
Additional Attenuation
Typ > 1 dB
N/A
–14dBm PWR meas
–15.5 dBm
–12.5 dBm
OTN Output Frequency
1070.9224 MHz
1070.9226 MHz
Page No.
Test Description
Min
Result
Actual
Max
panther3_iv.book Page 146 Wednesday, January 15, 2003 12:03 PM